Version 2.1.0.0 CRISP Logo CRISP Homepage Help for CRISP Email Us

Abstract

Grant Number: 1R43HL070350-01
PI Name: SHOUP, TIMOTHY M.
PI Email: tshoup@biostream.net
PI Title:
Project Title: Novel Tc-99m labeled rotenone complexes cardiac imaging

Abstract: The object of the proposed research plan is to develop a widespread clinical agent with improved tracer kinetics. The requisite for an optimal myocardial extraction characteristics and improved tracer kinetics. The requisite for an optimal myocardial blood flow imaging agent is accumulation in myocardium in proportion to true blood flow with prolonged retention in the myocardium. Such an agent would provide improved detection of mild coronary artery stenoses compared with other commercially available myocardial perfusion tracers. Radiolabeled rotenone analogs have been shown to posses excellent myocardial extraction characteristics over a range of blood flow making them promising clinical myocardial perfusion tracers. In this proposal we plan to develop a series of Technetium-99, (Tc-99m) labeled rotenone analogs and evaluate their myocardial kinetics compared to other flow tracers. The proposed research will determine the optimal structure features of technetium-99m labeled rotenone for the development of a myocardial blood flow imaging agent for nuclear medicine. Four [Tc- 99m) rotenone compounds containing different Tc-99m-chelation moieties will be synthesized and their myocardium extraction and biodistribution studied in rats. PROPOSED COMMERCIAL APPLICATIONS: Identification of an agent that accurately delineates myocardial flow non- invasively, would be of considerable benefit in the diagnosis and treatment of heart disease. The current market for cardiac flow tracers is greater than $300 million dollars per year. An improved product means increased market growth and improved patient care. In turn, accurate diagnosis affords improved patient management, and ultimately results in lower healthcare costs.

Thesaurus Terms:
blood flow measurement, chemical synthesis, heart imaging /visualization /scanning, plant insecticide, radiotracer, technetium
artery stenosis, nuclear medicine, perfusion, pharmacokinetics, radiopharmacology, single photon emission computed tomography
bioimaging /biomedical imaging

Institution: BIOSTREAM, INC.
160 2ND ST
CAMBRIDGE, MA 02142
Fiscal Year: 2002
Department:
Project Start: 03-JUN-2002
Project End: 02-JUN-2003
ICD: NATIONAL HEART, LUNG, AND BLOOD INSTITUTE
IRG: ZRG1


CRISP Homepage Help for CRISP Email Us